Needle is fixed by specialized attachment to evaluate the force of pulling out the needle apart from the hub for quality control and R&D. It enables testing according to the corresponding part of ISO and JIS standard.
Standards
- ISO 7864 (2016) [Sterile hypodermic needles for single use-Requirements and test methods] (corresponding part only)
- ISO 10555-5 (2013) [Intravascular catheters-Sterile and single-use catheters-Part 5: Over-needle peripheral catheters] (corresponding part only)
- ZTS series is recommended for this test.
- We offer custom-made products to perform this test. Please contact us for details.
- This video shows the testing image of objective sample. Some samples may not be suitable to measure with this configuration depending on their materials or shapes.
- The example of product configuration is for your reference only. It varies depending on sample, measurement method and testing capacity.
- The products used in this video may differ from the example of product configuration.
- Please select the right product model for the product configuration. Refer to the specification of each product for the compatibility.
Examples of Product Configuration |
---|
Standard Model Digital Force Gauge ZTS series |
Standard Type Vertical Motorized Test Stand MX2 series |
Attachment for Needle Bonding Strength Test MED-NPT-200N |
Force Control Cable (MX2/EMX - ZT connection) CB-528 |
Related Applications
-
Compression test of syringe
-
Compression test of syringe (Complies with the corresponding part of ISO 7886-1:2017)
-
Screw tightening/loosening torque test
-
Spot welding bonding strength test
-
Syringe needle penetration test
-
45-degree Pull Test of Solder Joints on QFP Lead (complies with the corresponding part of JIS Z3198-6: 2003)
-
Cable Crimp Terminals Tension Strength Test(Complies with the corresponding part of IEC 60512-16-4: 2008 and JIS C2805: 2010)
-
Cable ties loop tensile strength test
-
Clip Retension Test (Simple Manual Test)
-
Elasticity test of face mask band
-
Fabric bag handle tension test
-
High-Voltage Wire Harness Crimp Terminal Tension Strength Test(Complies with the corresponding part of JIS C2805:2010)
-
Opening operability test of helmet shield
-
Peel Test of Gable-Top Package (Manual)
-
Peel Test of Gable-Top Package Complies with the corresponding part of ISO 17480: 2015
-
Pull off test of elastic band from face mask
-
Pull Strength Test of Gull-wing Lead (complies with the corresponding part of IEC62137-1-1: 2007)
-
Pull-off Test of Coating (Complies with the corresponding part of ISO 4624: 2002)
-
Sewed decoration tension strength test
-
Shear Strength Test of Solder Joints on Chip Components (complies with the corresponding part of JIS Z3198-7: 2003)
-
Shear Strength Test of Surface Mount Solder Joint (complies with the corresponding part of IEC62137-1-2:2007)
-
Shear Strength Test of Surface Mounted Devices (complies with the corresponding part of IEC60068-2-21:2006)
-
Simple Corrugated Cardboard Sealing Strength Test
-
Spray Bottle Cap Insertion-Extraction Test
-
Strength and Sharpness Testing of Acupuncture Needle (Complies with the corresponding part of ISO 17218 : 2014)
-
Tensile Strength Test of Crimped Wire Terminals (Break Test) (Complies with the corresponding part of IEC 60512-16-4: 2008)
-
Tensile Strength Test of Crimped Wire Terminals (Durability Test) (Complies with the corresponding part of JIS C2805: 2010)
-
Tension strength and elongation test of thread
-
Tension strength test of hand wipes (non-woven)
-
Tension Strength Test of Polypropylene Strapping Band
-
USB connector extraction/insertion test
-
Zipper running smoothness test
-
Film Case Cap Pull Off Test
-
Flip Cap Opening Test
-
Glue Cap Pull Off Test (Simple Manual Test)
-
Pull Off Test of Medical Collection Kit Cap