High Capacity Tension Load Cell
ZU series

High Capacity Tension Load Cell ZU series

Inquiry about High Capacity Tension Load Cell ZU series

Usage/Specification Quote/Delivery Repair/Calibration

Feature

-High capacity load cell for tension.
-2 attached rod ends help mounting.
-IP 67 is approved. Waterproof and dust-proof.
-Connecting an amplifier is required to output force value.


Specifications for High Capacity Tension Load Cell ZU series

Model ZU series
Rated output +/-1.5mV/V
Nonlinearity +/-0.5% R.O
Allowable voltage 10V DC
Safe overload rating 120%
Working environment(allowable temperature) -10~50 degree Celsius(-30~50 degree Celsius)
Temperature influence at 0 point 0.005%/ degree Celsius
Temperature influence for output 0.005%/ degree Celsius
Cable ZU-10kN/20kN: Approx.5m
International Protection IP67

*IP is only approved for the load cell. An amplifier (an indicator)/ the connecting part/ the connector part are not approved.

Specifications for eZ-Connect series Load Cell

Model eZU series
Accuracy +/-1.0% F.S or less
Safe overload rating 120%
Working environment(allowable temperature) -10~50degree Celsius(-30~50degree Celsius)
Cable Approx.5m
International Protection IP67*

*IP is only approved for the load cell. An amplifier (an indicator)/ the connecting part/ the connector part are not approved.


Model List of High Capacity Tension Load Cell ZU series

Model eZ-Connect series Model Capacity
ZU-10kN eZU-10kN 10kN
ZU-20kN eZU-20kN 20kN

Dimensions

(Unit:mm)

ZU series dimension