Load Cell (Force Sensor)
DPU series

Force sensor
DPU-5N Load cell (Force sensor)

Inquiry about Load Cell (Force Sensor)DPU series

Usage/Specification Quote/Delivery Repair/Calibration

Feature

– Strain gauge type force sensor
– Easy to mount on your equipment with screws.
– For both tension and compression.
– Amplifier is necessary to read load values and output them to external equipment.


Specifications for DPU series Load Cell (Force Sensor)

Model DPU-2N~500N
Capacity Please refer to the model list.
Rated output 1mV / V±10%(2N, 5N is 0.9~1.25 mV/ V±10%)
Nonlinearity 0.12%R.O.
Hysteresis 0.12%R.O.
Recommended voltage(allowable applied voltage) 5V DC (12V DC)
Safe overload rating Please refer to the model list.
Working environment( allowable temperature) 0~+50 degree Celsius(-10~+60 degree Celsius)
Temperature influence for 0 degree 0.02%/ degree Celsius
Temperature influence for output 0.01%/ degree Celsius
Weight Approx. 325g
Cable 2m(with a connector)
Dimension Refer to dimensions.

 

Specifications for eZ-Connect series Load Cell (Force Sensor)

Model eDPU-2N~500N
Feature For standard force
Capacity Please refer to the model list.
Accuracy +/-0.2% F.S. or less
Safe overload rating Please refer to the model list.
Working environment( allowable temperature) 0~+50 degree Celsius(-10~+60 degree Celsius)
Weight Approx. 325g
Cable 2m(with a connector)
Dimension Refer to the dimensions.

Model list of DPU series Load Cell (Force Sensor)

Model eZ-Connect series model Capacity Safe overload rating Thread
DPU-2N eDPU-2N 2N 150% M6
DPU-5N eDPU-5N 5N
DPU-10N eDPU-10N 10N 200%
DPU-20N eDPU-20N 20N
DPU-50N eDPU-50N 50N
DPU-100N eDPU-100N 100N
DPU-200N eDPU-200N 200N
DPU-500N eDPU-500N 500N

Dimensions

(Unit:mm)

Dimensions for DPU series force sensor
pageTop