Product Search
Solution Search
Searchable by product name, product model or standard.
When searching by product model, enter the product model excluding the option code (-FA, -L, -NEXT, etc.).
*To search by solution, switch to “solution search.”
i.e., Load Cells, ZTA-50N, 7864 (for ISO 7864)
Searchable by you force type, industry, standard or product sample.
*To search by product, switch to “product search.”
i.e., Compression, 7864 (for ISO 7864)
SEARCH
Puncture Force
ISO
Graph
Medical devices and pharmaceuticals are used for diagnosis, treatment, and prevention of human and animal diseases, which are closely related to human and animal health. Therefore, high level of safety is required and many of these elements are strictly controlled by standards and internal regulations. This video shows how to perform a penetrability test of vial stoppers complying with ISO 8871-5: 2016. IMADA's specialized attachments, jig to fix the vial, Male Lure Slip Adapter to attach a hypodermic needle with 0.8 mm outer diameter (specified in the ISO standard), are used for this test. The peak force required for penetrating the vial stopper (rubber closure) is measured. The optional graphing software shows the entire force transition until the vial stopper (rubber closure) is penetrated, which helps you analyze the suitability of the vial stopper (rubber closure). It is used for the quality evaluation and quality control of vial.
inquiry number
1L2003A
Present the “inquiry number” below when you contact us, for prompt assistance.
ISO 8871-5 [ 2016 ] [Functional requirements and testing] (corresponding part only)
The lure fitting adapter in this configuration is MED-LFA-20N-MS, male lure slip type. Refer to the specification sheet for other options of the adapters.
When replacing the sample needles, remove the taper connector of the lure fitting adapter first from the force gauge to protect the sensor of the gauge from overloading. In the case the sum of the length of the needle and the height of the vial exceeds 185mm, the test stand is required to have long stroke option.
This video shows the testing image of objective sample. Some samples may not be suitable to measure with this configuration depending on their materials or shapes.
The example of product configuration is for your reference only. It varies depending on sample, measurement method and testing capacity.
The products used in this video may differ from the example of product configuration.
Please select the right product model for the product configuration. Refer to the specification of each product for the compatibility.
Convenient Unit/Torque/
Tension conversion
6 Significant Digits (*Significant digits are meaningful digits that do not include zeros, which are used to indicate the scale.)
Products
Attachments, Grips & Fixtures
Custom Made
Measurements in Special Environment
Temperature and Angle Adjustable Peel Tester
Spot Welding Pressure Gauge
Attachment to Bend Sample 90 Degrees
Horizontal Test Stand with Fine Adjustment Knob
Tester With Thermostatic Chamber
Tester With Far-infrared Heater
Table for Compression Load Cell
Test Stand for Testing at the Desired Position
Particular Samples Measurements
Peel Test Fixture for Crimped Postcard
Attachment for Fixing Wide and Thin Materials
Attachment for Wine Cork Extraction Test
Attachments for 90 degree score bend test
Attachments to measure forces to open flat pack carton
Attachments for break strength testing of lipsticks or lip balms
High capacity dual-column motorized test machine for compression test
Film Grip with Openable Gripping Part
Pantograph Grip with Pressurization Mechanism
Motorcycle Accelerator Torque Test Fixture
Peel Test Fixture for Solar Cell Ribbon
Test Stand With Large Table
Compression Test Attachment for LCD Panel
L-shaped Sample Fixture
Attachment for Opening/Closing Force Test of Takeout Container Lid
Attachment for Squeezing Force Test of Eye Drop Bottles
Compression Test Attachment for Squeeze Tube
Attachment for Welded Nut Tension Test
Attachment for Tube Tension Strength Test
Attachment for Hard-to-Grip Samples
Attachment for Compression Test of Nasal Spray
Individually Adjustable Torque Chuck Attachment
Resistance Force Measurement jig for Hair Combing Test
Attachment for Lateral Compression Test of Cup Containers
Water-Proof Shield for Motorized Torque Test Stand
Biaxial Tension Tester
Resize & Modification
Press Test Fixture (Wide Size)
Remote Control Switch for Motorized Test Stand
Semi-Customized Compression Attachments
Large Size of Compression Tester
Large Size of 90 Degree Peel Tester
Force Control Cable with Signal Output Box
Manual Test Stand with Displacement Output Option
Cutting Base Plate with groove and knife edge probe
Upper attachment for 4-point bending test
Main shaft stopper with a butterfly screw for MTS series
Wide Rubber Roller for Peel Test
Motorized Rubber Roller for Peel Test
Peel Fixture for Packaged Cooked Rice Lid
Cam grip with spring
Wedge Grip Without Adaptor
Customized Peeling Tester
Test Stand with 3-stage Force/Displacement setting/holding function
Torque Stand Shaft for Child Proof Lock Measurement
90 degree Peel Test Jig (High Capacity Type)
Tabletop Force Gauge Calibration Unit (High Capacity Type)
One-touch toggle clamp for Coefficient of Friction Fixture
Compact Motorized Test Stand
Tube Fixing Jig
Visualized Film Chuck
Tensile and Compression Torque Tester
Standards-Compliant Measurement
ISO 14704: 2000 Fine Ceramics 4-Point Bend Tester
Ampoule 3-Point Bend Tester
ISO/IEC 10373-1: 2006 Peel Tester of Identification Card
ISO 17480: 2015 Peel Tester for Gable-Top Package
ASTM D1894: 2014 Coefficient of Friction (COF) Tester
Attachments for score bend test
ISO 17480: 2015 45 Degree Complete Peel Test Fixture for Container Lid
IEC 61010-1 (2010) Spherical Jig for Compression Testing
ASTM D4032(Withdrawn 2025)Standard Test Attachment for Fabric Stiffness by Circular Bend Procedure
Peel Test Jig for Gable-Topped Package (No sample cut type)